In this paper, microelectromechanical system (MEMS) has been utilized to make miniaturized ion optics required for making the portable all-in-one mass spectrometer. Four different ion optics components were fabricated using deep-reactive ion etching (DRIE) of n-doped silicon-on-insulator. These components are 1 mm Bradbury-Nielsen gate, 500 µm coaxial ring ion trap (CRITter), reflectron optics and 500 µm Einzel lens. The Bradbury-Nielsen gate was made using a pattern of alternating electrode wires which either allows ions to pass or stop through the gate. The CRITter was made using five trapping rings and two end caps to make mass selection ion optics and it was also used in testing the alignment capability of fabrication process. The reflectron optics was made using a assembly of fifteen rectangular elements arranged in series. The fourth ion optics component was assembled MEMS Einzel lens which consisted of three lenses. It was used to focus the ions beam to increase the ion current and detectability. All the components were tested using ion produced with 70 eV EI ionization. These assemblies were characterized in terms of breakdown voltage, durability, and alignment. For current devices, the breakdown voltage was reported 750 V. The CRITter was tested with 1% toluene at pressure of 1 x 10-4 Torr. The resolution was limited due to the alignment errors and also aberration in etched designs got more impactful as the size of the ion trap was reduced. Current reflectron optics was not capable of resolving the peaks of toluene. Therefore, in the future analyzer path length will be increased by using multiple reflectrons. These miniaturized components were assembled using an encoded piezo-manipulator with pick and place capability. Resolution and ion attenuation was found to be the greatest concern of the current design at present.

Fox, J.; Saini, R.; Tsui, K.; Verbeck, G., Microelectromechanical system assembled ion optics: An advance to miniaturization and assembly of electron and ion optics. Review of Scientific Instruments 2009, 80 (9), 093302.

In this paper, a soft landing (SL) instrument has been developed with capability of depositing the ions onto the substrate for preparative analysis. The two important components of this instrument are custom made drift tube and two split rings. The drift tube is consist of 18 concentric rings along with two split rings at the end. The drift tube was filled with an inert buffer gas like He and operated from 1 to 100 Torr of pressure. High pressure gas thermalized the cluster ions on collision to 0.01 to 1.0 eV kinetic energy and separate the clusters formed by laser ablation. This helped in further analysis of deposited clusters on mica surface. Two functions of split-ring are to direct the cluster ions towards either detector or a landing surface. This instrument works on the principle of narrowing the kinetic energy of ions going through drift tube to prevent the fragmentation on landing. The gating function of split ring was performed using a homemade pulsing circuit that changes the voltage across the split ring. The SL instruments was built with a quick door CF flange which reduced the number of gaskets required and helped in holding, adjusting and removing the detector and landing surface from the instrument without disassembling the instrument. A simple Faraday plate was used in SL instrument as detector. A 15 mm mica disk used for atomic force microscopy (AFM) was used as landing surface. Split ring pulsing helped in selecting and isolating the specific ion clusters. For initial experiments copper was used as analyte and it was ionized using laser ablation using ND-YAG laser. Mass spectrum of Copper was reported to have multiple peaks due to Cun+, CunOm+ ions formation in the presence of O2 as contaminant. After the cluster deposition on mica surface, surface was analyzed using AFM and was compared with the physical vapor deposition (PVD). In the future, other landing surfaces like gold, silicon, and highly ordered pyrolytic graphite can be used to better understand the deposition mechanism.

infoRemember: This is just a sample from a fellow student.

Your time is important. Let us write you an essay from scratch

100% plagiarism-free

Sources and citations are provided

Find Free Essays

We provide you with original essay samples, perfect formatting and styling

Cite this Essay

To export a reference to this article please select a referencing style below:

A Study of the Use of Microelectromechanical Systems. (2019, March 12). GradesFixer. Retrieved June 15, 2021, from https://gradesfixer.com/free-essay-examples/a-study-of-the-use-of-microelectromechanical-systems/
“A Study of the Use of Microelectromechanical Systems.” GradesFixer, 12 Mar. 2019, gradesfixer.com/free-essay-examples/a-study-of-the-use-of-microelectromechanical-systems/
A Study of the Use of Microelectromechanical Systems. [online]. Available at: <https://gradesfixer.com/free-essay-examples/a-study-of-the-use-of-microelectromechanical-systems/> [Accessed 15 Jun. 2021].
A Study of the Use of Microelectromechanical Systems [Internet]. GradesFixer. 2019 Mar 12 [cited 2021 Jun 15]. Available from: https://gradesfixer.com/free-essay-examples/a-study-of-the-use-of-microelectromechanical-systems/
copy to clipboard
close

Sorry, copying is not allowed on our website. If you’d like this or any other sample, we’ll happily email it to you.

    By clicking “Send”, you agree to our Terms of service and Privacy statement. We will occasionally send you account related emails.

    close

    Attention! This essay is not unique. You can get a 100% Plagiarism-FREE one in 30 sec

    Receive a 100% plagiarism-free essay on your email just for $4.99
    get unique paper
    *Public papers are open and may contain not unique content
    download public sample
    close

    Sorry, we could not paraphrase this essay. Our professional writers can rewrite it and get you a unique paper.

    close

    Thanks!

    Your essay sample has been sent.

    Want us to write one just for you? We can custom edit this essay into an original, 100% plagiarism free essay.

    thanks-icon Order now
    boy

    Hi there!

    Are you interested in getting a customized paper?

    Check it out!
    Having trouble finding the perfect essay? We’ve got you covered. Hire a writer
    exit-popup-close

    Haven't found the right essay?

    Get an expert to write you the one you need!

    exit-popup-print

    Professional writers and researchers

    exit-popup-quotes

    Sources and citation are provided

    exit-popup-clock

    3 hour delivery

    exit-popup-persone